How to use refrigerant to empty the air conditioner after installation

  【】Air, the moisture and impurities contained in the air will cause pressure increase, current increase, noise increase, and power consumption increase in the air conditioner system, which will reduce the cooling (heat) capacity and may also cause Faults such as ice blockage and dirty blockage.

   At present, the air discharged from the indoor unit and pipeline is mostly ejected by the outdoor unit refrigerant:

  01), connect the pipe between the indoor unit and the outdoor unit The air pipe of the road is opened;

  02), use a hexagonal wrench to open the valve of the two-way stop valve on the outdoor unit to ensure that the refrigerant can enter the pipeline of the indoor unit;

  03), As the refrigerant slowly enters the indoor unit pipeline, the refrigerant gradually occupies the pipeline, ejects the gas in the indoor unit pipeline, and discharges from the opening of the disconnected thick pipe (trachea);

  04). When the refrigerant is seen to be discharged, quickly connect the air pipe to the three-way shut-off valve, tighten the tube, and the exhaust operation is completed.

  Note:

  1). The exhaust time 30s mentioned here is only a reference value. In actual operation, you must feel whether the sprayed gas has changed by hand. Cool to control the exhaust time.

  2) Mastering the exhaust time is very important for the use of air conditioners, because the exhaust time is too long, the refrigerant in the refrigeration system will be excessively lost, which will affect the cooling effect of the air conditioner ; Exhaust time is too short, the air in the indoor unit and pipeline is not exhausted, it will also affect the cooling effect of the air conditioner.

  3) Inverter air conditioners must be evacuated by vacuum, because this air conditioner mostly uses r410a refrigerant. This refrigerant is mixed in strict accordance with a certain ratio. If part of the gas is discharged by the headspace method, the ratio of the refrigerant will change and affect the refrigeration effect (after about a year of use, the effect on the refrigeration effect is obvious), so it cannot The refrigerant headspace method is adopted.

is a modern refrigerant gas widely used in start capacitor suppliers industry. It also enhances the quality start capacitor suppliers value of the products.

Hangzhou E cool refrigeration Co.,Ltd will accomplish this by exceeding the expectations of our customers while conserving resources and preserving the quality of the environment.

Hangzhou E cool refrigeration Co.,Ltd have been an established and popular company with an excellent track record for the best customer satisfaction.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect