How to judge whether the central air conditioning lack of refrigerant? - - - - - -

Central air conditioning system in effect in the process of using the cold poor is one of the most common problems for ordinary users, the lack of fluorine direct expression is also this kind of phenomenon, but the lack of fluorine is not the only cause of central air conditioning refrigeration effect is not good, so is there any intuitive judgment method to judge whether the central air conditioning fluorine missing? Easy and cool to tell you, first of all, we open the air conditioner, let air conditioning compressor continuous operation after 30 minutes, if the lack of fluorine in the refrigeration system, and can appear the following phenomenon. 1, the trachea dry valve. No cool sense of touch. This is because the lack of fluorine results in the decrease of the boiling point of refrigerant in the evaporator, the valve's refrigerant heat increases, the temperature of the valve. 2, liquid pipe valve frost. This is because the lack of fluorine in fluid pipe pressure drop, the boiling point is reduced, the valve temperature below freezing. 3, open the indoor machine panel, remove the filter, only a few can be found evaporator frosting. This is because the lack of fluorine cause lack of refrigerant, refrigeration area in decrease accordingly. 4, the exhaust air outdoor thermal. This is because the lack of fluorine refrigerant caused by insufficient, results in the decrease of condensing pressure and temperature. Five little or no drainage, drainage hose drainage. This is because the lack of fluorine in evaporator refrigeration area decreases, and also reduce condensation area, condensation water volume is reduced. 6, the gas and liquid valve have outdoor pollution. This is because the refrigerant and frozen oil has certain solubility, refrigerant from funnelled overflow oil after around funnelled, it also suggests that bad system closure resulted in the lack of fluorine. 7, from the fluoride mouth filling outdoor measuring pressure is lower than 0. 45MPa。 This is because the lack of fluorine causing shortages of refrigerant evaporating pressure drop. How, is not difficult, believe that the next time you encounter such problem won't freeze if again, go to try, have the effect very much, if still not, looking for regular maintenance factory to solve, must be careful operation, to avoid dangerous.

Hangzhou E cool refrigeration Co.,Ltd specializes in undertaking corporate offers to cater the needs of different companies.

Serving others for customers a better life with refrigerant gas for employees respect and opportunity.

Through our distribution and marketing competencies, Hangzhou E cool refrigeration Co.,Ltd provides creative, customized, solutions for our customers. As a result, we achieve superior profit growth as the air conditioner capacitor company of choice.

The best way to determine the ideal strategy of refrigerant gas is to continually test and refine your selling and marketing tactics.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect