ready to sign the corresponding air conditioning refrigerant, double gaps watch, thermometer, pressure gauge set current card table, a head connected hose refrigerant steel cylinder valves, a head of the double toki table center connector. Outdoor parts in low voltage side hose tubes on needle valve, valve should be opened before the fluorine bottle and table valve switch is a small amount of exhaust air, then tighten. Open air conditioning, set 'cooling' function, low temperature setting ( Add fluoride should set minimum in winter, and even the temperature sensing head in indoor machine heating) 。 After being compressor rotation, open of fluorine valve and inverted fluorine bottle, turn a circle table valve again, here is a refrigerant quickly into the thick copper tube. A few seconds, Is not beyond 10 seconds) After valve closed table, after waiting for air conditioning work for a few minutes, repeat. Touch the thick copper pipe, outdoor tubes should feel very cold, and condensate, the tube temperature should be between 5 to 15 degrees, add fluoride over ( Summer low pressure not to exceed 0. 6MPa) 。 Operation, the key problem is the right amount of fluorine, such as can according to the filling quantity of air conditioning nameplate, judgment should be adding quantity, scale into the best weights. By experience or thick tube temperature should be time to open the valve gradually to participate in, may not be too hurry too quickly. The lack of fluorine quantity, refrigeration, Heating) Role owe good, overheating and press; Take part in the quantity too much, the same refrigeration ( Heating) Role owe good, also can form high compressor load weight, system pressure, add power consumption, compressor overload pressure maintenance and system maintenance, compressor intermittent work, liquid impact, very simple, such as damage to the compressor or other accidents. Also need to tip is here, never rely on pressure alone or how much current to determination of fluorine content, because is a variable pressure and current, along with the concave and convex of environmental change. Each rise or fall of 5 degrees, pressure or current will rise or fall of 10%.
more related to the refrigerant products http:///product/
tag: & nbsp  & NBSP refrigerant & NBSP fluorine refrigerantis frequently used by people in daily life since it can improve start capacitor suppliers and start capacitor suppliers.
Hangzhou E cool refrigeration Co.,Ltd’s mission is to be the leading global innovator, developer and provider of refrigerant gas start capacitor suppliers products, systems, and services.
While the productivity and efficiency benefits of automation are unequivocal for manufacturing air conditioner capacitor, the need for skilled humans to operate, utilize and advance technologies is equally unmistakable.
Simultaneously being able to offer not only the product but also the service, gives the customer a quality 'one-stop-shop' service.