2019 - 05 - 15, as you know, for each refrigeration equipment, the refrigerant is very important and very much refrigerant at present and that there is no lack of among them there are a lot of the inferior products, coupled with the imperfect refrigerant sales channels on the market, so that part of the fish in troubled waters of refrigerant is filled with the market. Here share some ways to distinguish those refrigerants of reference. Suggested by the following methods to identify whether for inferior refrigerant: 1, whether through formal channels to purchase normal manufacturer production of refrigerants, such as price significantly lower than the market price of refrigerants, should be on high alert. 2, if you have the test conditions, it is recommended to use before the refrigerant to test its purity and acidity, significantly lower than the industry standard for the test result of refrigerant is not recommended. Note: qualified purity of R22 refrigerant should be greater than 99% ( High quality refrigerant purity is more than 99. 8%) , acidity, In HCL) Should be less than 0. 0001. 3, if you do not have refrigerant test conditions, it is recommended to use simple check, before the refrigerant can simple inspection method is: the refrigerant tank inversion, and release a small amount of refrigerant to a piece of white paper, if there is a obvious impurity in white paper or liquid water, poor quality of refrigerant, is not recommended; Connect pressure gauge test refrigerant cylinder, control the refrigerant temperature and pressure characteristics, test whether the pressure in the bottle in the normal range, such as the abnormal pressure obviously is not recommended. And the refrigerant used in the middle, can test the pressure in the bottle again. For refrigerant R22 this single component, two bottles of pressure measurement value should be very close to, but for inferior refrigerants, often mixed with a variety of ingredients, refrigerant in bottle after use due to the change of composition usually there will be a large bottle of pressure difference, if encounter this kind of phenomenon, advice immediately stop using the refrigerants, and would like to have filling to the emissions of refrigerant in the system clean to avoid pollution system. In system debugging phase, if found abnormal phenomena as follows: system refrigeration capacity obviously insufficient and through inspection found no other exceptions need to focus on the condition of the refrigerant; System dryer filter or expansion valve block, and the blockage is tan wax-like or black sludge need to focus on refrigerant when foreign body; System during operation, abnormal high and low pressure or temperature (or stop state system balance abnormal pressure To control the refrigerant temperature and pressure characteristics) , need to focus on refrigerant. When these anomalies, Suggestions from the system makes a purity test of refrigerant to screen inferior refrigerant risk. And in the meantime, it is suggested that the refrigerant compressor side drain or released the refrigerant in the system, in order to avoid potential inferior refrigerant and compressor contact and damage the compressor. Once found caused by chemical pollution caused by inferior refrigerant compressor fault, unit parts or so had to use the same source in the field of refrigerant units ( Even if the unit can work normally) Also need to replace the refrigerant. Because of the effect of dangerous chemicals in the inferior refrigerant is sometimes slow, may result in system failure after a long time.
air conditioner capacitor are all following the most compatible manufacturing regulations.
Energetic, optimistic entrepreneurs often tend to believe that sales growth will take care of everything, that Hangzhou E cool refrigeration Co.,Ltd will be able to fund our own growth by generating profits.
Hangzhou E cool refrigeration Co.,Ltd’s model also predicts (i) a positive effect of management on firm performance; (ii) a positive relationship between product market competition and average management quality (part of which stems from the larger covariance between management with firm size as competition strengthens); and (iii) a rise (fall) in the level (dispersion) of management with firm age.
There are so many factors that businesses have to weigh when producing refrigerant gas, and we are not going to pretend to grasp all of them.