How to deal with after machine leakage fluorine?

to refrigeration unit fluorine first to know the processing of refrigeration unit leakage reasons of fluorine, find the cause of the failure can be reasonable for processing, and reduces the leakage of the refrigeration unit fluorine losses to people.

1, the refrigeration system leak detection point: should make the entire refrigeration system filled with normal refrigeration dose; Main detection refrigeration system are: indoor and outdoor connection pipe joint, the process inlet (outdoor Plunger parts) Every leakage inspection shall not be less than 3 minutes, especially outside the machine stop valve, bell mouth, fixed with nut silk mouth, must use a mirror to observe, the leak detection of here is most important, but more neglected leak detection.

2, the cause of the problem: indoor and outdoor connecting pipe shall not besmear freezing oil. Measures: to repair the bell, the frozen oil evenly in the interior and exterior joint connecting pipe.

3, the cause of the problem: the bell mouth and stop valve surface or within the machine evaporator before the connection is not fixed in the middle of joint, deviation is too big, cause the fastening is not uniform. It is understood that at present our country has become a veritable air conditioner production country. At present, China's household air conditioner industry total production capacity of 26 million units to 33 million units, about a third of total world production; And the refrigeration industry in China fully 'the fluorine', many will make air conditioning, the refrigerant.com/refrigerant-gas' target='_blank'>refrigerator enterprises facing big test cost. Before the implementation of the Montreal protocol multilateral fund project, household refrigeration industry of refrigerators, freezers CFC - should be used in production process 12 as refrigerant, the use of CFC - 11 as insulation foaming agent. All-China environment federation, said in an interview, the head of the production of freon, mostly in the form of some industrial products used refrigerants, so looking for new cfc-free refrigerants, has become an imminent event. As the cold storage of refrigerant also must have a corresponding improvement according to introducing, at present the United States, Japan and other developed countries as cold storage has not ozone-depleting hydrogen fluorine refrigerant hydrocarbon refrigerants as standard product. Maintenance methods: hand bell mouth is first fixed in the center of the joint position, fastening nut fixed at the same time, guarantee the fixed in position.

4, the cause of the problem: the whole machine has funnelled refrigeration system. Treatment measures: check carefully there are oil pipeline; Use tools such as halogen leak detector, or sponge coating machine will not be too thick soap water cooling system pipe, weld parts for leak detection, detection conditions require refrigeration system, nitrogen, or fluorine filling leak detection in an all-round way, find out funnelled in turn.

5, the cause of the problem: the connecting pipe outside side not fixed measures, to loosen the bell mouth fixation. Maintenance methods: to repair the bell, the connecting pipe fixed tightly.

6, the cause of the problem: the bell mouth making bad leakage caused by fluorine: bell mouth edge overlap; Flaring before cutting connecting pipe appear skewed; Connection caused by uneven thickness bell made wall thickness is not uniform; Bell mouth size is too small or too large; The lining of chip; Flaring a burr; Bell mouth tear; Bell the wound. Measures: flaring process in strict accordance with the requirements of production bell, bell form the surface is smooth, uniform, avoid squeeze out a small bell mouth sealing surface is too small; Connection GuanPing straight, it is forbidden to use without finishing bending uneven expansion of connection pipe system bell mouth.

7, the cause of the problem: indoor and outdoor connecting line is good after, to bind up or adjust the line to the position, the fixed bell mouth loose. Maintenance methods: to repair the bell mouth and tighten. First of all, before not tighten bell adjust connecting pipe to reach the designated position, then tighten the bell mouth.

Hangzhou E cool refrigeration Co.,Ltd is committed to fulfill the demands of our customers with using refrigerant gas.

Hangzhou E cool refrigeration Co.,Ltd will be known for our leadership edge, through our passion for high standards, our respect for diversity and our commitment to create exceptional opportunities for professional growth so that associates can fulfill their highest potential.

To offer abundant options of product is an important factor to a company, such as air conditioner capacitorstart capacitor suppliers to afford high-quality products for customers.

refrigerant gas has a very good repute over the global market.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect