loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

How to correctly judge refrigerants of true and false, you know? _

In real life, we all know, no matter what products to buy, is really false, refrigerant is not exceptional also, so how to judge refrigerants of true and false? Below small make up to introduce a few methods, let's learn together. 1, the refrigerant cans upside down, and release a small amount of refrigerant to a piece of white paper; If there is obvious on the white paper impurities or liquid water, poor quality of refrigerant, suggest not to use. 2, refrigerant cylinder pressure gauge testing, control the refrigerant temperature and pressure characteristics, check whether the pressure in the bottle in the normal range; If pressure apparently unusual, is not recommended. 3, the refrigerant used in the middle, the pressure inside the bottle test again. For refrigerant R22 this single component, two measuring bottle pressure value should be close. If the refrigerant is inferior refrigerants, often mixed with a variety of ingredients, refrigerant in bottle after use due to the change of the composition proportion, usually there will be a bigger difference, the pressure in the bottle if encounter this kind of phenomenon, suggest to stop the use of the refrigerant, and should be timely to the refrigerant emptying has been injected into the system, to avoid damage to the system. 4, in the system debugging phase, if it is found that the following anomalies, suggests purity tests on refrigerant in the system, whether the discharge refrigerant in the system for poor quality. System refrigeration capacity obviously insufficient and through inspection, found no other exceptions need to focus on the condition of the refrigerant; System dryer, filter or expansion valve block, and the blockage is tan wax-like or black sludge need to focus on refrigerant when foreign body; Appeared in the process of system running high, low pressure or temperature anomaly, or stop state, abnormal pressure system balance, need to check the refrigerant. Above introduction about the refrigerant to the over here, hope to be able to bring you some help, if you have a demand on refrigerant, welcome consultation discussion with us, we wholeheartedly at your service.

Hangzhou E cool refrigeration Co.,Ltd is trying to institute social good changes this relationship because it averts a firm's resources from its core task of increasing profits.

Hangzhou E cool refrigeration Co.,Ltd is a company that offers reliable products. For customization, start capacitor suppliers and start capacitor suppliers in different styles are also in the offer list. Click Arkool Refrigeration for more details.

Hangzhou E cool refrigeration Co.,Ltd is a initial company that supports expertise in searching marketing solutions.

Hangzhou E cool refrigeration Co.,Ltd always believes that the average profitability of our company is sufficient.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect