loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

How to choose refrigerant for different types of industrial chillers?

  【】We all know that the working temperature of medium and high temperature chillers can be controlled between 3~35℃, low temperature chillers can also be controlled at 0~-60℃, and ultra-low temperature chillers can even reach -60~- 120 ℃, and according to the different temperature range, their choice of refrigerant is also different.

  The carrier refrigerant is an indispensable part of the safe operation of industrial chillers, but due to the different working temperature and the requirements/features of the chiller, the choice of carrier refrigerant is different. According to the working temperature range of the chiller, the applicable range of various refrigerants and the specific method of selecting the refrigerant: 1. If the working temperature of the industrial chiller is above 3℃, then the system Generally, water is used as the refrigerant carrier. This is because water z* is easy to obtain and low in price, and the water has good chemical stability, high specific heat, non-toxic, non-flammable, non-explosive, and less corrosive to metals than salt water. . However, the freezing point of water is high (the freezing point is 0°C under atmospheric pressure), which greatly limits the use of water as a refrigerant in the refrigeration system;

  2, if the working temperature of the industrial chiller is 3~ In the range of -60°C, sodium chloride aqueous solution or calcium chloride aqueous solution is generally used as the refrigerant. However, due to the limitation of freezing point, sodium chloride brine is suitable for refrigeration systems at 3 to -16°C, while calcium chloride brine can be used in refrigeration systems at 3 to -50°C. Brine is also very common as the refrigerant of the chiller refrigeration system. It has a wide temperature range, is affordable, and has a large heat capacity. However, it has a certain corrosive effect on metals, so many users will also choose ethylene glycol or The aqueous solution of glycerol is used as the refrigerant (only used in refrigeration systems above -30°C). When the temperature is outside this range, trichloroethylene or methylene chloride can be used instead of calcium chloride.

  3. When the working temperature of industrial chillers is lower than -50℃, hydrocarbons with lower freezing points are usually used as refrigerants, such as trichloroethylene, methylene chloride, ethanol, acetone Etc., and their boiling point is also very low, so a closed system is generally used to prevent pump cavitation and reduce evaporation loss.

air conditioner capacitor start capacitor suppliers, as the name suggests, find extensive use in start capacitor suppliers institutions. Since start capacitor suppliers has become much dependent on technology in today's world, there is wide use of such refrigerant gas.

Super quality are in offer at Arkool Refrigeration, welcome to visit us.

Hangzhou E cool refrigeration Co.,Ltd's core technology of air conditioner capacitor enables us to understand and utilize in a right way.

Hangzhou E cool refrigeration Co.,Ltd have significantly changed the way customers approach manufacturing. refrigerant gas can still compete if we are willing to change the ways in producing.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect