How to choose cold storage refrigerant

Refrigerants can be mainly divided into two categories: ammonia refrigeration system and freon refrigeration system. These are the 'ammonia storage' and 'fluorine storage' that we usually refer to. If you want the best use of the cold storage, you must choose the refrigerant reasonably. Only in this way can the performance of the cold storage be more stable and help save users' energy consumption. As a professional cold storage construction company, Refrigeration believes that the refrigerant of the cold storage refrigeration system should be selected reasonably according to the cold storage refrigeration method:

1. Direct expansion liquid supply

The refrigerant directly passes through the refrigerator, the expansion valve of the accumulator, and then flows through the evaporator and cooling pipe, to the evaporator and cooling pipe, so as to achieve the role of providing refrigerant to the cold storage. Although this method of use is relatively simple, it is difficult to control the amount of liquid supplied by the refrigerant, and it is easy to affect the cooling effect of the entire cold storage. It is a relatively common refrigeration method for Freon refrigeration systems.

2. Gravity liquid supply

Gravity liquid supply is also a commonly used refrigeration mode in cold storage, which is added between the evaporator and the expansion valve A gas-liquid separator, after the refrigerant reaches a certain amount of liquid, directly supplies the static pressure of the liquid column, and supplies the refrigerating liquid to the cooling equipment of the cold storage. For this refrigeration mode, the most commonly used refrigerant is ammonia refrigeration, which can pass through the ammonia liquid separator to provide enough refrigerant to the refrigeration equipment of the cold storage to ensure the normal operation of the refrigeration system.

3. Pump circulating liquid supply

Pump circulating liquid supply is also known as ammonia pump liquid supply, which can be divided into upward and downward There are two ways of outlet and bottom inlet and top outlet. Both of these methods can effectively ensure the supply of refrigerant in the refrigeration system of the cold storage, and send the refrigerant to each refrigeration equipment to achieve the best cooling effect. The adjustment of the liquid supply of the ammonia pump, but it is better to have multiple pipelines, which can adjust the liquid passing through, so that it can supply liquid to the refrigerating room, freezing room and other places to ensure the cooling effect.

Whether it's automation or artificial intelligence, the rapid convergence of technology and business often determines air conditioner capacitor’s competitiveness.

Hangzhou E cool refrigeration Co.,Ltd has been a leading server of for many years. Visit the website Arkool Refrigeration for quality refrigerant gas.

We sells air conditioner capacitor and focus on operational procedure and manufacturing facilities start capacitor suppliers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect