How to check the air conditioning refrigerant leaking

1。 Fluorescent leak detection, namely using fluorescent leak detection agent in the uv/blue light leak detection will announce the principle of bright yellow green, for all kinds of system of fluid leakage testing, but everything using PAG lubricant used in the early years of the compatibility with everything is poorer, because the leaks to find oil stains, fluorescent leak detection agent also lost. 2. Soapy water leak detection, that is, to the system of filling the pressure a 0. 98 - 1. 96 mpa of nitrogen, and then the system each part coated with soap and water, bubble point is the leakage point. 3. Halogen leak detection, after will leak detection lamp lighting, the air on the handheld halogen lamp tube line close to the refrigeration system, when the pipeline leakage, flame color becomes purple blue, using this way to leak detection is open, the more risk, and flame combined with refrigerant can produce harmful gases, moreover also difficult to accurately locating funnelled. 4. Electronic leak detection, the probe will leak detection equipment to the possible leakage parts move, announced the alarm if leak detection equipment, that everything I say here. 5. Section pressure test, that is, making special joint jig, and pressure testing of equipment, pipe separation, this is a more reliable leak detection method.

more relevant content query http:///news/

Finding a reliable solution for the air conditioner capacitor start capacitor suppliers not only supports operation of the entire system but also enhance the beauty of your workplace.

Hangzhou E cool refrigeration Co.,Ltd aligns itself with customers as partners to assist them in achieving their goals and objectives.

The lower cost of refrigerant gas, compared to other product, and Hangzhou E cool refrigeration Co.,Ltd’s services provide may well suit the needs for customers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect