Today as the capacitor manufacturer under the first to introduce the air conditioning is how to change air conditioning capacitor: 1: use soldering iron to dismantle capacitance. 2: install new capacitance. 3: to use. Down to teach people to judge the stand or fall of capacitor, there are the following three methods, consult for everybody to learn: method 1: the most direct the most simple way: use 220 v alternating current (ac) connected directly, we can pick up a pole, with another power cord touch another capacitance feet. In touch to see if there are obvious small spark, is certainly the capacitance charging, that is to say, the capacitance not bad. How air conditioning capacitor in method 2: pointer multimeter, also can use the digital meter capacitance measurement file. If use pointer multimeter, general use R x 1 k file, pens and respectively connected to the poles of capacitance. Multimeter pointer will swing at this moment, then slowly back to zero or near zero. The capacitor is good. The greater the capacity of capacitor, the longer the charge time, pointer swing are more slowly in the direction of 00. If, after connect a pointer still shows very little resistance does not move, you can be sure is bad. Method 3: digital multimeter detection with digital multimeter to check, to set the digital multimeter to the appropriate resistance, red pens and and black pens and contact the poles of the measured capacitor, respectively. At this point, the display value will increase, beginning from 000 until the display symbols '1'. If always shows 000, internal short circuit capacitor. If always show overflow, may be internal capacitor electrode open, may also be a choice of resistance is not appropriate. In order to see from the screen of capacitor charging process, with different capacity of the capacitor should choose different resistance of gear. Select resistance principle is: capacitor is larger, should choose low blocking; Capacitor capacity is small, should choose high resistance. If small capacity were examined with a low blocking capacitor, due to the charging time is short, always show overflow, can't see the change process, which has open easily mistaken for capacitor. If check high-capacity capacitor in high resistance gears, the charging process is very slow, need a measuring time and long. For 0. More than 1 ~ 1000 uf capacitor can choose resistance (according to the following table The charging time in table display file changes from 000 to the time needed for overflow) 。 To measure for the selection of resistance, capacitor, resistance ( Ω) Tested capacitor range ( uF) Charging time ( S20M0。 1 ~ 12 ~ 122 m1 ~ 102 ~ 18200 k10/19 dated to 1003 ~ 2020 k100 ~ 10003 ~ 132 k > 1000 > 3 capacitor after breakdown or open, can't repair, only change is the new capacitor. For ease of repair when choose, in the following table lists the capacity of the capacitor and the compressor motor output power matching, for your reference. Capacitor capacity and compressor motor output power matching compressor motor output power ( W) 0. 2, 0. 4, 0. 75, 1. 0 and 1. 5, 2. 0, 2. 2, 3. 0 and 3. 7, 4. 0, 5. 0; Capacitor capacity ( uF) 15, 30, 40, 50, 20, 30, 50, 50, 75, 75, 100.

start capacitor suppliers are required in the manufacture of almost every product and start capacitor suppliers refrigerant gas is one of the most common machines.

Hangzhou E cool refrigeration Co.,Ltd seeks to lead the industry by instilling pride in our customers, creating value for the market and sharing responsibility around the world.

start capacitor suppliers air conditioner capacitor will help keep your start capacitor suppliers in a start capacitor suppliers state.

We studied how market-leading companies are harnessing data to reshapeHangzhou E cool refrigeration Co.,Ltd, and explored how they can put data to work for us in ways that create value for our own businesses.

Hangzhou E cool refrigeration Co.,Ltd knows how important it is to offer optional extras, such as refrigerant gasstart capacitor suppliers to provide quality products for customers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect