How to add refrigerant when the air conditioner is not cooling?

1. Filling Freon by the high-pressure valve 1. The injection method is next to the high-pressure valve. There is a special fluorine-filled hose with a thimble through the hole. First, tighten the thimble connector to remove the air in the hose, and then open the valve , Inject Freon into the high pressure side of the air conditioner at the valve port. 2. Tips When the pressure in the body and the container is balanced, Freon will stop flowing into the machine. At this time, warm water can be used to heat, increase the temperature, once to increase the pressure in the container, so that the Freon liquid continues to flow into the refrigerant.com/hfc-refrigerant' target='_blank'>refrigeration system. The compressor must be kept stopped during the entire operation. 3. Matters needing attention Generally, freon filling from the high-pressure side is suitable for equipment with a large number of filling or equipment with liquid storage, and freon will be weighed in advance. When the conditions for “weighing” are not available, the filling volume is estimated by experience. For equipment that does not have liquid storage or requires precise filling volume, part of the freon can be supplemented or discharged according to the method of filling freon from the low pressure valve. 2. Low pressure Valve filling freon 1. When the air conditioner with small applicable demand requires less refrigerant, the method of filling freon gas from the low pressure side is generally used. This method is slow in filling speed, but easy to control and safe. 2. Injection method There is also a special hose next to the low pressure valve. The other end of the hose is connected to the meter valve. First connect the freon container to the meter valve (if you need to vacuum, connect the vacuum pump and then transfer the freon container). Tighten the thimble connector and use the The freon vapor flushes out the air in the hose. 3. How to balance the pressure? After filling the refrigerant, start the air conditioner, and after the operation is stable, observe the low pressure pressure value to judge the amount of freon in the system, if it is insufficient, open the container valve , Continue to inject freon gas into the refrigeration system, while observing and controlling the low pressure pressure, and finally adjust to the standard evaporation pressure of the air conditioner. Fill freon from the low pressure valve, and freon enters the system as a gas. When the gas pressure in the container is the same as the pressure in the system When balancing, warm water can be used to heat the freon container to increase the gas pressure and make it easier for freon to flow into the system. Do not turn freon capacity upside down during operation to prevent 'liquid hammer' accidents.

Hangzhou E cool refrigeration Co.,Ltd has a professional team of engineers and technology professionals.

We are an experienced supplier of and have gained good reputaion among global customers. With a wide range of in offer, we can customize according to your requirement. Send us your enquiry at Arkool Refrigeration.

For more air conditioner capacitor start capacitor suppliers reviews, tips and advice on choosing a washer and dryer for you and your family, please visit Arkool Refrigeration,where you can also choose the you are looking for.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect