Refrigerator refrigeration, like air conditioners, is achieved through refrigerants. Some people said that there is no refrigerant in their refrigerators. In fact, the refrigerant in the refrigerator is enough when you buy the refrigerator. Therefore, the refrigerator that has just been put into use does not need to add refrigerant to it. It will be done when the refrigerant is gone. How to add refrigerant to the refrigerator? The editor will take everyone to find out!

1. First establish the system connection, first close the high and low pressure valves; need to measure the low pressure port, blue tube, low pressure quick connector of the refrigerator and the low pressure phase of the refrigerator system Connect and lock it; then connect the high-pressure port, the red tube, the high-pressure quick connector and the system high-pressure phase measurement and lock it; then connect the filling port, the yellow tube and the vacuum pump and tighten them.

2. Vacuum extraction of the refrigerator system. This step must be carried out under the normal pressure of the system, otherwise, the system should be depressurized first. After completing the above connections of the refrigerator system, first turn on the vacuum pump, and at the same time, open the high and low pressure valves, and then (open the high and low pressure quick connectors), at this time the system starts to evacuate; after a certain period of time (about 10~30min), check whether the system is complete Vacuum, if there is no vacuum, check the system for leaks and re-evacuate after repair; at the same time, close the high and low pressure valves, and then turn off the vacuum pump; keep the pressure for 3-~5min to check if there is any leakage in the system;

< /p>

3. Fill the system with refrigerant, disconnect the yellow tube from the vacuum pump, and then connect it to the refrigerant bottle and tighten it; first open the refrigerant bottle (position in the forward direction), and then open the The valve core exhausts the air in the yellow tube, then invert the refrigerant bottle and put it away; at the same time, open the high and low pressure valve, add refrigerant to the system, and close the high and low pressure valve when the specified amount (according to the filling amount provided by each system manufacturer) is reached. Positive refrigerant bottle.

4. To confirm the filling effect, turn on the system first; after a certain period of time (about 5~10min), check whether the high and low pressure of the system is normal (refer to the system manual). If it is insufficient, open the low-pressure valve slowly (it is strictly forbidden to open the high-pressure valve at this time), replenish the appropriate amount of gas refrigerant (the cylinder is placed in the state), and then close the low-pressure valve, and then re-test; if it is too high, close the cylinder. Slowly open the high-pressure valve, discharge an appropriate amount of refrigerant from the valve core of the meter group (at this time, pay attention to the sprayed refrigerant hurting people), then close the high-pressure valve, and re-test; repeat the same as above until it is normal.

5. Turn off the system, first turn off the refrigerant bottle and high and low pressure quick connector, drain the remaining refrigerant in the meter group from the valve core of the meter group (at this time, pay attention The sprayed refrigerant hurts people), then remove the high and low pressure quick connector (at this time, pay attention to high temperature and hot hands), remove the refrigerant bottle, remove the three-color tube, and keep it properly.

How to add refrigerant to the refrigerator is mainly to connect the refrigerant system to the refrigerator, and just add the refrigerant in the corresponding steps. If you are not familiar with refrigerators, you must find a professional to add refrigerant, and you must pay attention to safety!

Hangzhou E cool refrigeration Co.,Ltd has various branches in different countries worldwide.

If you have any issues with your air conditioner capacitor, you will have to call the experts at Arkool Refrigeration to assist you. Any of your enquiry is warmly welcomed.

The success of refrigerant gas of campaigns largely rides on how you market your company to the crowd.

Hangzhou E cool refrigeration Co.,Ltd can assure that it is one of the best products in the market at present.

Consumers like these are interested not just in air conditioner capacitor they will spend their money on, but also in the human and environmental impact of the supply chain that produces those goods.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect