loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

How to add refrigerant to the air conditioner, this operation can save a lot of money!

When should you add refrigerant to the air conditioner, do you really know? Today, the editor takes everyone to add refrigerant without having to spend money to hire a master! When these two situations occur, it means that you should add refrigerant to the air conditioner!

First, when we can clearly feel that the cooling effect of the air conditioner has dropped significantly, it may be necessary to add refrigerant for the air conditioner.

Second, when the refrigerant is insufficient due to leakage or other reasons, it needs to be overhauled and refrigerant added.

How is the air conditioning and refrigerant process? How much pressure or weight must be added to meet the cooling conditions of the air conditioner.

1. Turn on the air conditioner and start the compressor to ensure that the added refrigerant is at the correct value;

2. Twist off the nut on the main tube of the outer machine and use Tighten the tube that is directly opposite to the refrigerant surface. Don’t make any noise of leaking the refrigerant. Connect the other tube outside the refrigerant surface to the refrigerant tank;

3 、Look at the approximate pressure of the refrigerant table first. If there are more types of refrigerant, you can add a little more refrigerant for a long time. If there are fewer types of refrigerant, then you need to add more slowly for a long time. Otherwise, the refrigerant Adding too much will turn the cart before the horse and affect the refrigeration effect;

4. Open the refrigerant tank, and then open the refrigerant meter valve, turn it on and off for a rhythmic addition, don’t open the refrigerant meter valve at once. Finish, it will cause the refrigerant meter to be washed out in severe cases;

5. When the pointer is only between 0.4MP-0.5MP, it means that the pressure is sufficient, and you can test the temperature of the air outlet of the inner machine. If you think it’s not very cold, you can add a bit more and check the temperature of the outside machine. If the temperature of the wind blowing out is too high and it is hot, you can put a little refrigerant;

6. Close each valve tightly. Take off the refrigerating watch and sprain the nut, and add the refrigerated to finish.

In addition, some friends find it troublesome and are unwilling to operate by themselves, and generally choose air conditioning after-sales service. At this time, we must pay attention: if the air conditioner in the home needs to add refrigerant, it is best to let the installer use a vacuum pump to evacuate the air conditioner, and then add the refrigerant, which will help ensure the service life of the air conditioner compressor.

Anxious in finding a solution to your air conditioner capacitor issue? Click Arkool Refrigeration to find a top start capacitor suppliers refrigerant gas company offering top quality .

Hangzhou E cool refrigeration Co.,Ltd didn’t receive any negative feedback from our customers before, which proves that customers have faith in us.

With this competency, Hangzhou E cool refrigeration Co.,Ltd provide high technology and assist customers to create added value and contribute to the development of producing air conditioner capacitor.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com