How to add refrigerant r410a correctly

how to add refrigerant r410a correctly? Believe that many people don't know it, it doesn't matter, here small make up for everyone to do the introduction, let's learn together.

higher than r410a refrigerant R22 refrigerant pressure about 1. Six times or so, so, in the process of construction and after-sales service in case of wrong operation, is likely to be a major accident. When installing a R410A refrigerant air conditioning, using R410A special tools and materials, pay attention to safety operation.

( 1) Before operation, confirm the name of air conditioning refrigerant, and then to the operation of the different refrigerant implementation, in the use of R410A refrigerant in household air conditioner, must not be used outside of the refrigerant R410A in using R22 refrigerant air conditioner, also cannot use R410A refrigerant.

( 2) If there is leakage of refrigerant in the operation, ventilation is carried out in a timely manner, please.

( 3) During installation, mobile air conditioning, please don't will R410A refrigerant outside air mixed with air conditioning refrigerant circulation line. If mixed with air and non-condensable gas, will lead to abnormal high pressure refrigerant circulation pipeline, the circulation line is the main cause of fracture, crack.

( 4) After the installation work, please confirm carefully, there can be no refrigerant leakage phenomenon. If the refrigerant leakage in indoor, once with the electric fan, heating furnace, electric appliances, sparks of toxic gases will form.

( 5) When installing a yituo more air conditioning, due to the volume of the refrigerant sealed more, especially in the small room for installation, even one thousand refrigerant leakage occurs, its concentration cannot exceed the specified value. Otherwise, will cause the phenomenon of hypoxia.

( 6) When in installation, mobile air conditioning, please according to the requirements of specification and reliable. When improper installation will cause refrigerant circulation line work is not normal, water leakage, electric shock, fire wait for a phenomenon.

( 7) Please don't secretly to air conditioning, please professional personnel for repair. Repair improper will cause water leakage, electric shock, also cause fire wait for a phenomenon.

the above about the r410a refrigerant is introduced to this end, hope to be able to bring you some help, if you have a demand on refrigerant r410a, welcome consultation discussion with us.

There are many issues that affect start capacitor suppliers, which has led to the need of getting specialists trained in certain areas so as to handle all issues that may arise as well as air conditioner capacitor products that can solve start capacitor suppliers problems.

We humbly ask you to use refrigerant gas and we guarantee that you would be in a great delight with using the product.

When it comes to air conditioner capacitor start capacitor suppliers, Hangzhou E cool refrigeration Co.,Ltd is the name to reckon with. Not only are they best, they are the most experienced as well and provide wide range of services as well as products at affordable prices. Find out more information on Arkool Refrigeration.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  CHEMLONG CO.,LIMITED / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect