How do I know how much Freon is in the air conditioner?

It is based on this principle:

1. The most direct method is to observe whether the outdoor unit has a heat sensation after the air conditioner compressor is running, and there is a heat sensation. Freon is enough, no need to make up. No heat sensation requires further investigation.

2. If there is less Freon in the air conditioner, it is usually caused by the leakage of the refrigeration cycle pipeline, which directly causes the refrigerant pressure in the refrigeration pipeline to be low, and also directly causes the air conditioner compressor to run, but it does not feel too cold. And the suction pressure and discharge pressure of the compressor should both drop. The pressure value in the refrigeration pipeline depends on the specific conditions of the selected compressor. There is a reference value. The refrigerant pressure hovering between 1.7MP and 1.9MP is a suitable pressure. Insufficient refrigerant, the evaporator in the evaporator drops significantly, so after the compressor is running, it feels not too cold. At the same time, the normal operation of the compressor is indirectly affected, and the working current of the compressor is lower than the rated current.

There are many ways to judge the lack of fluoride in air conditioners, but most of them require professional tools to measure it, but ordinary judgments can also be made by the following methods:

p>

1. The air-conditioning effect is getting worse, and the temperature is obviously low, but you don't feel the coolness, it may be fluoride deficiency!

2, the outdoor unit of the air conditioner frequently starts and stops, and it is obvious that the indoor temperature does not reach the set temperature, and the outdoor unit will still shut down. It may be the compressor overheating protection caused by the lack of fluorine!

3. The noise of the outdoor unit becomes louder, and the compressor that lacks fluorine will always be in high-frequency operation, so the noise will be significantly increased!

4. There are obvious oil stains in the outdoor connecting pipelines, and there will be oil stains in the leakage of Freon. You can test it with detergent and water!

5. The low-pressure pipe of the air conditioner (that is, the thin pipe we see) has frosting, and it is judged that it is caused by the lack of fluoride!

The above is the answer to the related questions about how to know how much Freon is in the air conditioner. Have you learned it?

is frequently used by people in daily life since it can improve start capacitor suppliers and start capacitor suppliers.

You can count on Hangzhou E cool refrigeration Co.,Ltd to be your one stop shopping site for most of the quality products you are searching for. We strive to offer a wide variety of products for you to learn about and to purchase. 

Using high technology, air conditioner capacitor showed its competitive advantages, captioned with information about the company's commitment to providing safe, reliable, profitable jobs to local artisans.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect