High and low temperature box filling operation method of freon refrigeration system

high and low temperature box filling freon refrigeration system operation method is as follows:

1, prepare a scale, weighing the freon cylinders, records of usury, gross weight.

2, put the cylinder on the scale, with the x1 copper tube, with authoritarian threads on one end connected to the cylinder, the other end to a compressor suction valve of the multi-purpose on channel, multi-purpose channel nut will not enter the wrenching, first open the cylinders, then turn off again, is the sort of air inside the receiving, then the nut and tighten.

3, freon are filling the wet steam way, so to properly when you opened the steel cylinder valves, liquid impact to prevent compressor attack. Unscrew the multi-purpose channel on the compressor suction valve together and start filling refrigerant. If the system is a vacuum situation, the refrigerant inside the cylinder can be injection system actively, stay inside the system pressure balance, pressure and the cylinder cooling punishment enters suspend. At this time if the system refrigeration dose not foot, can first closed steel cylinder valves, accumulator outlet valve, expansion valve and the compressor suction valve manually, a condenser cooling water pump, and then to start the compressor. In order to avoid the liquid cylinder, and should be gradually open the suction valve, all the refrigerant system pumped in accumulator, some and is pumped into the vacuum system of low pressure, and then opened the steel cylinder valves, let the refrigerant active pumping system again.

4, so repeated, foot system until the required refrigeration dose. Can after the system was sleeve into vacuum, opened the accumulator outlet valve and small open expansion valve, let the system normal operation, and then opened the steel cylinder valves, and gradually close the suction valve ( The open multi-purpose channel) , let the refrigerant in a cylinder, depending on the difference between the pressure and suction pressure into the bottle and system ( Should pay attention to not liquid impact) 。 When filling to meet the requirements, want to go to the closed steel cylinder valves, then have receive the residual refrigerant sucked into system as much as possible, eventually closed multi-purpose channel, to suspend the compressor operation, filling refrigerant basic to complete homework.

tag: & nbsp  & NBSP freon

Currently there is a global trend growing. People are more conscious about start capacitor suppliers and are seeking alternatives to traditional solutions.

go to Arkool Refrigeration to get an amazing offer at favorbale price. the refrigerant gas start capacitor suppliers actually works and is worth a try.

Arkool clearly and succinctly expresses what our company is all about. Strong brands cut through the noise to grab the audience and immediately shed light on the character of the product or service.

Hangzhou E cool refrigeration Co.,Ltd will do this by managing our business with integrity and the highest ethical standards, while acting in a socially responsible manner with particular emphasis on the well-being of our teammates and the communities we serve.

With wide range of [分类关键词] products of top quality in offer, Hangzhou E cool refrigeration Co.,Ltd will definitely be your best option for air conditioner capacitor solution. Do feel free to contact us at Arkool Refrigeration.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect