Guidelines for the use of R410a refrigerant and R22 refrigerant

Compared with the most common refrigerant R22, r410a has many performance advantages and good heat transfer. Its main performance advantages are reflected in the following aspects:

1. Compared with R22, the R410a system has a significant advantage: the evaporator The heat transfer is 35% higher, and the heat transfer of the condenser is 5% higher.

2. Its cycle working pressure is about 57% higher than that of HCFC-22, the refrigeration capacity per unit volume is about 43% larger than that of HCFC-22, and the coefficient of refrigeration is about 7.7% smaller than that of HCFC-22. The rest of the parameters are similar to HCFC-22. -22 is basically close.

3. Under the same mass flow rate, the pressure drop of R410a is relatively small.

4. Compared with the R22 system, the system matched with R410a can use a smaller volume condenser and evaporator, and can reduce the refrigerant charge by up to 30%.

5. The loss in the compressor compression process is lower, the evaporator and condenser have stronger heat transfer, and the pressure drop in the entire system is smaller, so the same cooling capacity and the same condensing temperature Among the systems, the energy efficiency ratio (COP) of the R410a system is 6% higher than that of the R22 system.

2. Installation and maintenance considerations:

1. The pressure of R410a is about 1.6 times higher than that of R22 refrigerant. When installing R410a refrigerant in air conditioners When using R410a special tools and materials, pay attention to safe operation.

2. Please do not mix air other than R410a refrigerant into the air conditioner's refrigerant circulation pipeline. If air and other gases are mixed in, it will cause abnormal high pressure in the refrigerant circulation pipeline, which is the main cause of rupture and cracks in the circulation pipeline.

3. If the refrigerant leaks indoors, it will form toxic gas once it comes into contact with an open flame.

4. Unlike other refrigerants used in the past, it is easily affected by impurities such as moisture, oxide layer, grease, etc. Therefore, full attention should be paid to the construction operation, and clean piping should be used to prevent moisture, etc. Mix in.

5. Since R410a is a simulated azeotropic mixture refrigerant, when adding refrigerant, use a liquid method. When adding refrigerant, use refrigerant container and electronic scale for weight measurement.

6. The pressure of household air conditioners using R410a refrigerant is much greater than that of traditional R-22 refrigerant. Therefore, in terms of material selection, it must be compatible with R410a. Copper pipes with a wall thickness of 0.7mm are available in the market and must not be used.

7. The pressure of R410a is relatively high, and the previous multi-pipe measuring meter cannot be used. The high-pressure standard and low-pressure meter are different from previous products. The following parameters can be referred to when purchasing a pressure gauge.

8. Once the R410a refrigerant is mixed with the lubricating oil (mineral oil) of the vacuum pump, a chemical reaction will occur and sludge will be produced, resulting in damage to the air-conditioning components.

9. The special refrigerant container for R410a is directly marked with the name of the refrigerant, and at the same time, it is also marked in color (pink) in accordance with the requirements of ARI in the United States.

10. The previous R-22 testing products cannot be used. A high-sensitivity leak detector dedicated to HFC refrigerant must be used.

Hangzhou E cool refrigeration Co.,Ltd, the best suppliers of domestic markets, has good faith in manufacturing.

Hangzhou E cool refrigeration Co.,Ltd plans to produce and execute four marketing seminars, one per quarter, to help business owners see success by sharing important growth strategies and hosting interactive workshops.

air conditioner capacitor continued to evolve to having strong manufacturers develop huge marketers and people came to value their opinions about what to buy.

Hangzhou E cool refrigeration Co.,Ltd must adopts new technology and internal procedures to increase responsiveness and mitigate costs going forward.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect