Matters needing attention of film capacitor

1, the selection of working voltage film capacitor depends on the highest voltage applied, and the applied voltage waveform, current waveform, frequency, ambient temperature, Capacitor surface temperature) , the influence of factors such as the capacitance. Before use, please check at the ends of the capacitor voltage waveform, current waveform and frequency ( In high frequency, allowing with different types of capacitor voltage change, details please refer to the manual) Whether in the rating.

2, working current through the capacitor pulse ( Or communication) Current is equal to the capacitance C and the product of the voltage rising rate, is I = C x dv/dt. Because the capacitor loss, under the condition of high frequency or high pulse when used by pulse capacitor ( Or communication) Current can make the condenser heat and temperature rise, there will be thermal breakdown ( Smoke and fire) The danger. Therefore, the capacitor safety conditions of use not only by the rated voltage ( Or category voltage) Restrictions, and restricted by the rated current. Rated current is considered to be determined by the breakdown model of pulse electric current ( Peak current, that is limited by the index of dv/dt) And continuous current ( Expressed in fengfeng values or RMS) Composition, when using, must make sure both current within the scope of the permit. Under the condition of high frequency or high pulse capacitor used, we recommend polypropylene film capacitor or MPES fold chip capacitor. PPS, MPPS, MPSA series high-pressure polypropylene film capacitor is given duty ratio ( 责任) Was 15% of the rated current fengfeng values. MPP, MPH, MPA series S correction capacitor rated fengfeng value current is given. Under no circumstances do not allow more than the rated value of fengfeng current use. When actual working current waveform and the waveform is not at the same time, given the polyester film capacitor in their temperature is 10 ℃ or less under the condition of use, polypropylene film capacitors in itself under the condition of temperature is 5 ℃ or less use, capacitor surface temperature is not allowed to exceed the maximum rated temperature.

3, flame retardancy, although outside the film capacitor encapsulation were used in the fire resistance - flame retardant materials - Flame retardant epoxy resin or plastic shell ( UL94 / V - Level 0) , but outside of the continuous high temperature or flame can still be outside the core deformation produced by the capacitor encapsulation is broken, and led to the condenser core melting or burning.

4, restrain power electromagnetic interference with capacitor when using capacitor to eliminate noise in power across the line, not only the normal voltage, there will be abnormal pulse voltage ( Like lightning) Smoke or fire happens, this may lead to capacitor. Line across the capacitor, therefore, its safety standards in different countries have strict rules. Please use a MKT61, MKP61 type capacitor safety certification. Is not recommended to capacitor used as capacitor across the line.

5. Depends on the capacitance of capacitor charging and discharging the capacitor charge and discharge current and voltage rise rate of the product, even if it is low voltage to charge and discharge, may also produce large moment of charge and discharge current, which can cause damage to the performance of capacitor, such as short circuit or open circuit. When the charge, please series a 20 ~ 1000 & Omega; / V or higher current limiting resistor, charge and discharge current limit within the prescribed scope. When more than one film capacitor in parallel to withstand voltage test and life test, please for each capacitor in series a 20 ~ 1000 & Omega; / V or higher current limiting resistor. See the capacitor for standard

6. Flame retardant: although outside the film capacitor encapsulation were used in the fire resistance - flame retardant materials - Flame retardant epoxy resin or plastic shell, but the outside of the continuous high temperature or flame can still be outside the core deformation produced by the capacitor encapsulation is broken, and led to the condenser core melting or burning.

7. The surface temperature rise ( △ T ) : 7. 1 when the capacitor is used in communication and pulse occasions, flowing through the capacitor current makes the fever, if the heat is too big, can lead to short circuit capacitor and even burn. So the current flowing through the capacitor cannot exceed the maximum value stipulated in the product catalog and capacitor when load monitoring temperature rise is particularly necessary.

Hangzhou E cool refrigeration Co.,Ltd has various branches in local businesses, servicing customers and helping to pull in traffic to those businesses.

We are dedicated to providing you with more than just customer service by utilizing our qualified team who pride themselves on meeting and exceeding customer's needs. We also have ell-equipped plantin China with advanced facilities to manufacture start capacitor suppliers refrigerant gas products according to customers requirements. Welcome to send your enquiry and visit our factory. Our website is Arkool Refrigeration.

By balancing the efficiencies of new technologies with the personal touch of highly trained and motivated professionals, Hangzhou E cool refrigeration Co.,Ltd is able to deliver solutions and services that exceed our customers’ expectations. We thereby earn their loyalty.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect