loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Explosive and the conventional characteristics and applications of refrigerant R290 refrigerant R32

In general, easy to explosive refrigerants in transportation, the application will have certain disadvantages, is also one of the refrigerant type of high attention. And is currently widely used 32 refrigerants and R290A refrigerant is a typical explosive refrigerants. See in what are the characteristics of it, they know that there is no danger. R290( Hydrocarbon refrigerants) Product introduction and operating safety and health hazards: a simple asphyxia and anesthetic effect. 1% propane brief contact and do not cause symptoms; Concentration below 10%, only cause mild dizziness; Can appear when contact with high levels of anesthesia, loss of consciousness; Very high concentrations can cause choking. Dangerous characteristic: flammable gas, mixed with air to form explosive mixture, heat and flame is in danger of burning explosion. Small amount of filling and the amount of refrigerant R290 is only 40% ~ 55% of R22, r410a, less dosage, more economical. Low freezing point, latent heat of evaporation is bigger, makes the unit time cool faster; Small isentropic compression than power, make compressor work more easily, extend the service life of the compressor; Small molecular weight, good liquidity, lower delivery pressure, reduce the load of the compressor. Use of R290 refrigerants, energy-saving rate can reach 15-35%. R290 'flammable and explosive' the deadly disadvantage of highly destructive. R290 can form explosive mixture mixed with air, heat and flame is in danger of burning explosion. This leads to production line and product safety problems. 'Is afraid of ten thousand but one thousand' psychological, once in the country in case of R290 air conditioning blast will cause consumer panic, as a result, the domestic production and promotion of R290 refrigerant air conditioning is very cautious. R32 refrigerant R22 alternative basic properties are R32, R32 refrigerant ozone-destroying ozeme depletion potential ( ODP) Coefficient values (0, global warming GWP) 0. 11, work pressure and R410A. Under the same refrigerating capacity, R32 filling amount is only about two-thirds of R22. R32 than R290 with only low flammability, compared with R410A, R32 coefficient of global warming is only about a third of the former, these advantages make it become the most potential one of the main substitute for R22. R32 of energy-saving, green, do not damage the ozone layer also become one of the modern new refrigerant of refrigerant. So pay more attention to the general characteristics of refrigerant and safe use of rules, flammable and explosive of various models, don't literally used as refrigerant amateurs filling by youself, lest hurt its own security.

Hangzhou E cool refrigeration Co.,Ltd has famous reputation in worldwide.

As a result, consumers will reward Arkool with leadership sales, profit, and value creation, allowing our customers in which we live and work to prosper.

Arkool focuses on three key elements—process, people, and technology—the authors found that people of two seemingly opposite cultures are able to work together in a project-based environment to complement each other and reap mutual benefits for a win-win result.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect