loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Encountered in refrigeration equipment debugging operation phase three of the following are generally used inferior refrigerants

< p > used in refrigeration equipment debugging operation phase are generally inferior refrigerant is easy to cause the three problems: < / p > < p > < / p > < p > 1) Refrigeration equipment refrigeration capacity obviously insufficient and through inspection found no other exceptions need to focus on the condition of the refrigerant; < / p > < p > < / p > < p > 2) Refrigeration dryer filter or expansion valve block, and the blockage is tan wax-like or black sludge need to focus on refrigerant when foreign body; < / p > < p > < / p > < p > 3) Operation process of refrigeration equipment, abnormal high and low pressure or temperature or refrigeration equipment balance when abnormal pressure (stop condition To control the refrigerant temperature and pressure characteristics) , need to focus on refrigerant. When these abnormal phenomena, it is suggested that extracting refrigerant tested for purity, to screen inferior refrigerant risk. And in the meantime, it is suggested that the refrigerant compressor side drain or release all refrigerant refrigeration equipment, in order to avoid potential inferior refrigerant and compressor contact and damage the compressor. < / p > < p > < / p > < p > once found caused by chemical pollution caused by inferior refrigerant compressor fault, unit parts or so had to use the same source in the field of refrigerant units ( Even if the unit can work normally) Also need to replace the refrigerant. Because of the effect of dangerous chemicals in the inferior refrigerant is sometimes slow, may be after a long time cause refrigeration equipment failure. < / p > < p > < / p >

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect