Emergency treatment methods and urgent measures for R22 refrigerant leakage

refrigerant.com/hfc-refrigerant' target='_blank'>R22 refrigerant has low toxicity, but some of the cracked gas and residual liquid components produced by using it to prepare tetrafluoroethylene are highly toxic and can cause acute poisoning. People who are mild after poisoning may have cough, chest tightness, dizziness, fatigue, and nausea. Animal experiments show that R22 refrigerant has anesthetic effect and cardiotoxicity. So what is the emergency treatment method for R22 refrigerant leakage? What first-aid measures should be taken when the human body comes into contact with R22 refrigerant? Take a look at the answers of experts in the refrigeration market.

R22 refrigerant leakage emergency treatment method:

Delimit the warning zone according to the affected area of u200bu200bthe gas, and evacuate irrelevant personnel from the crosswind and upwind direction to safety Area. It is recommended that emergency response personnel wear positive pressure self-contained breathing apparatus and general work clothes. Do not touch or cross the spill. Cut off the source of leakage as much as possible. The sprayed water suppresses the vapor or changes the direction of the vapor cloud to prevent the water from contacting the leakage. It is forbidden to directly impact the leakage or the source of leakage with water. Prevent the diffusion of gas through sewers, ventilation systems and confined spaces. Leaked gas is allowed to be discharged into the atmosphere. Keep the leaking place ventilated.

What first-aid measures should be taken when the human body comes into contact with R22 refrigerant:

Skin contact: Take off contaminated clothing immediately, and rinse with a large amount of flowing water for 20-30 minute. If you feel uncomfortable, seek medical advice. Eye contact: Lift the eyelids immediately and rinse them thoroughly with plenty of running water or normal saline for 10-15 minutes. If you feel unwell, seek medical advice; inhalation: leave the scene quickly to a place with fresh air. Keep the airway unobstructed. If breathing is difficult, give oxygen. If breathing and heartbeat stop, cardiopulmonary resuscitation should be performed immediately. Seek medical attention; ingestion: will not be exposed through this route.

Owing to its start capacitor suppliers and start capacitor suppliers benefits, has become a buzzword in the start capacitor suppliers market.

Growing revenue is a common goal for many businesses. We want to be sure Arkool include leaders from the marketing, sales and production departments to help make certain that the goals we choose are appropriate and have strong support.

refrigerant gas are less complex compared with start capacitor suppliers.

The start capacitor suppliers air conditioner capacitor is an all-servo system capable of storing hundreds of start capacitor suppliers process parameters to provide custom start capacitor suppliers profiles for each start capacitor suppliers type and start capacitor suppliers configuration.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect