Do you really understand the R410A refrigerant

do you really understand R410A refrigerant? Believe that many people see this problem will consider seriously, really know about it? Don't understand it doesn't matter, here small make up together and see it.

r410a is a displacement in the residential and small commercial air conditioning and heat pump system instead of R - 22 HFC refrigerants. It is R - 22 have higher refrigeration capacity and significantly higher pressure, can only be used for R - 410 a dedicated system. Replace

R410A in major global trends and prospects of use conditions of the international market and dynamic R410A physical properties data of entering the international market, is a kind of mixed refrigerant, it is by R32 ( Methylene fluoride) And R125 ( Five fluorine ethane) Consisting of a mixture, its advantage is that can be used according to the specific requirements, for a variety of properties, such as flammability, capacity, exhaust gas temperature and efficiency into consideration, tailored to synthesize a kind of refrigerant.

R410A refrigerant colorless appearance, not cloudy, volatile, boiling point - 51. 6 ℃, freezing point - 155℃; Its main features are:

( 1) Does not destroy the ozone layer. Its molecular formula does not contain chlorine, therefore its ozone depletion ozeme depletion potential ( ODP) To zero. Global warming ozeme depletion potential ( GWP) Less than zero. 2.

( 2) Toxicity was low. Permissible concentration and R22, too, are 1000 PPM.

( 3) Don't burn. The flammability of 0 in the air.

( 4) High chemical and thermal stability of

( 5) Water solubility and R22 is almost the same.

( 6) Is mixed refrigerant, is composed of two kinds of refrigerants

( 7) Not with mineral oil or alkyl benzene oil miscibility.

R410A refrigerant is a mixed refrigerants composed of HFC class material, do not contain any ozone-depleting substances, its ODP value is zero. Compared with R22, R410A refrigerating capacity significantly increased, so for the design of air conditioning equipment to smaller and more compact. And because the R410A has nearly azeotropic property, within the scope of the whole operation, coolant temperature glide less than 0. 2 ℃, R410A refrigerant in the refrigeration and air conditioning system will not occur significant separation, which will not change the composition of refrigerant due to leak, so in the process of after-sales maintenance add, don't need to discharge off the rest of the refrigerant in the system. R410A is the world recognized household air conditioning refrigerant R22 medium replacement.

refrigerant R410A cylinders for pressure container, storage should be away from fire and heat source, prevent sun direct insolate, often store in a cool, dry and ventilated warehouse. Should be light, light discharge when handling to prevent damaged cylinders and valves and other accessories.

the above relevant introduction about the R410A refrigerant over here, hoping to bring some help, if you have a demand on refrigerant, welcome consultation discussion with us, we wholeheartedly at your service.

Hangzhou E cool refrigeration Co.,Ltd is experienced in producing start capacitor suppliers refrigerant gas products featuring topnotch quality with ODM services available. Welcome to visit our site at Arkool Refrigeration.

Energetic, optimistic entrepreneurs often tend to believe that sales growth will take care of everything, that Hangzhou E cool refrigeration Co.,Ltd will be able to fund our own growth by generating profits.

Looking for Manufacturers in China? Then Hangzhou E cool refrigeration Co.,Ltd is the right choice. we are a well known start capacitor suppliers air conditioner capacitor Manufacturers and suppliers from China.

Time is one of the biggest challenges cited by manufacturing refrigerant gas.

Further dialogue of Arkool between the approaches, the chapter concludes, could lead to actionable advice on more robust policies that drive both structural change and competitiveness upgrading.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect