loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Do you know the skills of choosing refrigerants?

No matter what product we use, there are some of their own skills, and refrigerants are no exception. Do you know what are the techniques for choosing refrigerants? It doesn't matter if you don't know, the editor below will take you to find out.

Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south. It is a working substance that continuously circulates in the refrigeration system and realizes refrigeration through its own state changes. The refrigerant absorbs the heat of the cooling medium (water or air, etc.) in the evaporator and vaporizes, and transfers the heat to the surrounding air or water in the condenser to condense.

The selection of refrigerant is a relatively complex technical and economic issue. There are many factors to be considered. When selecting, an overall technical analysis should be carried out according to the specific situation.

1. Consider the requirements of environmental protection. Choose refrigerants that comply with national environmental protection regulations.

2. Consider the requirements of refrigeration temperature. According to different refrigerant temperature and cooling conditions, high temperature (low pressure), medium temperature (medium pressure), and low temperature (high pressure) refrigerants are selected. Usually the standard evaporating temperature of the selected refrigerant is 10°C lower than the refrigerating temperature. The choice of refrigerant should also consider the cooling conditions and use environment of the refrigeration device. Automobile air conditioners can only use the air outside the car as the cooling medium. The temperature, wind speed, solar radiation, heat radiation and other factors that affect it frequently change. Its operating conditions determine that it can only use high-temperature (low-pressure) refrigerants. In the past R12 is used, and R134a is mostly used when posting.

3. Consider the nature of the refrigerant. According to the thermal, physical and chemical properties of the refrigerant, select those refrigerants that are non-toxic, non-explosive, and non-combustible; the selected refrigerant should have good heat transfer, low resistance, and good compatibility with the materials used in the refrigeration system.

4. Consider the type of compressor. Different refrigeration compressors work differently. Volumetric compressors increase their pressure by reducing the volume of refrigerant vapor. Generally, refrigerants with large refrigeration capacity per unit volume are used, such as R134a, R22, etc. There are many types of refrigerants, with the advancement of science and technology. New working fluids are constantly appearing to suit different refrigeration devices.

This is the end of the above introduction on how to choose refrigerants. I hope to bring you some help. If you have a demand for refrigerants, please contact us for consultation and negotiation. We will serve you wholeheartedly!

In an age when refrigerant gas is increasingly important, the researchers believe manufacturers should pay close attention to their results.

Hangzhou E cool refrigeration Co.,Ltd has had manufacturing experience for over start capacitor suppliers years. She currently runs a website where they sell . You can visit her site at Arkool Refrigeration.

Hangzhou E cool refrigeration Co.,Ltd employs a group of professional staff, enhancing the function of air conditioner capacitor.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect