in Chinese household air conditioning, there are four commonly used refrigerant R22, r410a, R32, R290, that these are what features, let's look at the characteristics of them.

1, the physical and chemical properties:

refrigerant name

R22

R290

R410A

R32

formula

CHClF2

C3H8

CH2F2 / C2HF5 ( Mixture)

CH2F2

molecular weight

86. 47

44。 1

72。 58

52。 02

2, environmental protection features:

refrigerant name

R22

R290

R410A

R32

the ODP

0. 0 05

0

0

GWP

1810

two

2100

675

3, toxicity aspects: specific data are shown in table 1, four kinds of occupational exposure limit of refrigerant volume concentration, the same relative R22, R32 and acute toxicity of R410A is lower, and R290 slightly higher.

4, combustion characteristic aspects: from the burning lower limit temperature, automatic lighting, minimum ignition energy, combustion rate and combustion heat five metrics ( Specific value shown in table 1) , the flammability of R290 was much higher than that of R32, R290 is A3 level security and R32 A2L safety level. Non-combustible, R22 and R410A A1 security levels.

note: burning level is divided into: 1 No flammable, 2 - Moderate combustible, 3 - Highly flammable, 2 l - The combustible. Highly flammable refrigerants are: R290 and R1270, R600a, R161, etc; Micro flammable refrigerants are: R32, R717, R1234yf, etc.

5, saturated vapor pressure, the index is higher, the higher the system pressure requirements

refrigerant name

R22

R290

R410A

R32

%

100%

89 ~ 93%

157 ~ 159%

162%

6, density, the smaller the parameter values, the smaller the refrigerant filling quantity

refrigerant name

R22

R290

R32 saturated liquid density

100%

41. 2% ~ 41. 78年

4%。 6% ~ 82. 8%

saturated vapor phase density

100%

41. 1% ~ 45. 103年

4%。 6% ~ 112. 1%

7, specific heat at constant pressure, the indexes, the greater the heat transfer effect, the better.

refrigerant name

R22

R290

R32

liquid phase specific heat capacity

1

2. 13 ~ 2. 186 times

1. 484-1. 649 times

saturated gas heat capacity than

1

2. 313-2. 425 times

1. 653-2. 083 times

8, phase change latent heat: the indexes, the greater the heat transfer effect better and refrigerant mass flow rate, the smaller cycles.

refrigerant name

R22

R290

R32

%

1

1. 825-1. 841 times

1. 401-1. 552

9, filling quantity contrast: the direct response filling quantity index relative size.

refrigerant name

R22

R290

R410A

R32

%

100%

40%

113%

91%

10, compared with R22, thermodynamic cycle analysis conclusion is as follows:

theory to investigate and compression ratio, under a given thermal conditions, investigate the cannot reflect the actual effect, here don't give a conclusion.

exhaust temperature: the better the reliability index is lower, the compressor

refrigerant name

R22

R290

R410A

R32

nominal working condition of refrigeration

0

- 16. 8℃

+ 4。 8℃

+ 13。 5 ℃

high temperature working condition of refrigeration

0

- 20. 7℃

+ 5。 4℃

+ 17。 1 ℃

the quality system of refrigeration/heat: the smaller the index, the greater the refrigerant circulation flow.

refrigerant name

R22

R290

R410A

R32

nominal working condition of refrigeration

100%

177. 101年

1%。 152年

5%。 5%

nominal working condition of heating

100%

177. 2%

105. 156年

3%。

4%

come in many forms, like start capacitor suppliers and start capacitor suppliers, and they all provide efficient solution for our start capacitor suppliers needs.

To receive more professional tips and super quality products for start capacitor suppliers, go to our website Arkool Refrigeration to place your order. Do not wait any longer.

In conjunction with retraining and upskilling efforts, Hangzhou E cool refrigeration Co.,Ltd’s workers should focus on growing unique human skills that high-tech machines are unable to replicate, such as strategic and abstract thinking, complex communications, creativity and leadership competencies.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect