Commonly used air conditioning refrigerant performance comparison

at present, the common air conditioning on the market for refrigerant R410A and R22 and R407C.

410 a can from the characteristics of thermal engineering drawing is analyzed, the evaporation temperature - 40 ~ 10 ℃, within the scope of the steam density is 43% higher than that of R22, r410a latent heat of vaporization ratio R

considering the compressor efficiency loss, the same enclosed using R410A compressor refrigerating capacity will be about 50% higher than that of R22. If the optimization design of R410A system to replace R22 system, considering the decrease of flow, as well as the working medium circulation flow reduce caused by the heat exchanger, pipe, control the original size decrease factors, such as for small power air conditioning, R410A equipment cost may be cheaper than R22 equipment. But for high power air conditioning, high pressure steam to run the equipment investment and the increase of the weight it may become a question. Because with the increase of cooling load, R410A and weight of equipment needed for the safe operation of the investment will be rapid growth.

in environmental protection technology development and use of refrigerant R410A and R407C, should according to their different applications and different load in different environmental protection refrigerants:

( 1) For condensation at a lower temperature, such as water, using R410A technology can reduce the size of our equipment, improve the coefficient of performance.

( 2) Load the smaller type air cooling air conditioning system, such as rated load is 4 kw, by adopting the technology of R410A, can obtain higher coefficient of performance, and can control equipment investment.

( 3) For air cooling type air conditioning load is larger, there are two development trends, from the ease of development and investment saving perspective, R407c is better than that of R410A. Because of the former's very close to R22; From the perspective of improving coefficient and reduce equipment size, R410A better.

( 4) For the current R22 equipment renovation project, using R407C is more reliable than using R410A, not only low cost, and simple.

start capacitor suppliers air conditioner capacitor is liked by everyone and is used in every household.

To know more about refrigerant gas, please check our website at Arkool Refrigeration.

Technology upgrades can pay for themselves quickly by improving air conditioner capacitor and enabling employees to accomplish more in less time. It may be time to focus on start capacitor suppliers to ensure they run smoothly and efficiently.

Knowing what promotions are popular and get the most activity as refrigerant gas from current and potential customers can play a role in your overall strategy.

We focus on operational procedure and manufacturing facilities of air conditioner capacitor.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect