loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Common freon refrigerant and liquid ammonia refrigerants compared advantages and disadvantages

The study found that can be used as refrigerant refrigeration industry only dozens of different material, but also more than ten kinds of commonly used in industrial refrigeration. Then using liquid ammonia and freon in succession. Now, the water is used only for injection and absorption refrigerants, sulfur dioxide is used for the raw material of dry ice. Sulfur dioxide and chlorine methane have now almost don't have to. Currently widely used in the compression machine refrigerant liquid ammonia and freon. Liquid ammonia liquid ammonia is a refrigerant in general use in industry. It has the advantage of low boiling point, moderate pressure, refrigerating capacity is big, the unit volume throttling losses small, dissolved water, leakage was found, the price is low. Liquid ammonia itself also has its unavoidable disadvantages: toxic, stimulation, when contact with water for copper and its alloy ( Except for phosphor bronze) Corrosive, mixed with air explosion, high temperature decomposition of volatile. Freon freon is the halogen derivative of saturated hydrocarbons, their molecular general formula is: CmHnFxIyBrz, and there are 2 m + 2 = n + + y + z xo. Most of freon refrigerant is non-toxic and tasteless. Don't burn under refrigeration system temperature, no explosion danger, and good thermal stability. Freon big molecular weight of the wettability of metal. The downside is the refrigerating capacity is small, the unit volume throttling loss is big, than major, number of thermal conductivity is small. Flame stimuli will decompose into toxic gas, it is expensive. In recent years, scientific studies have found that freon with a strong damage of atmospheric ozone layer, is one of the important causes to produce the greenhouse effect. Freon refrigerant R12 (which are frequently used CF2Cl2) ,R22( CHF2Cl2) , including R12 RGE of greenhouse effect relative coefficient is 1. 0. Freon refrigerant and ammonia refrigerant which is better? About this problem, the library of China refrigeration expert will bring your users to a detailed comparison. Ammonia refrigeration system, just as its name implies is to use eucalyptus to act as the refrigeration system of refrigerant, because the love fluid of low prices, good evaporating temperature, daily needs spending maintenance is less, so is the most common refrigerants. And freon refrigeration system is to use the service to act as refrigerants, than ammonia refrigerant, the use of freon cost will be high, but the cooling effect is far higher than that of ammonia refrigerating machine, its price is quite high. Second, freon refrigeration system cooling pipe is quite complex, of an ammonia refrigeration system, the use of safe is the biggest advantage of freon refrigeration system. It is well known that ammonia refrigerant quite volatile and diffusion, with its strong excitant odour, can damage the body's respiratory tract and skin mucous membrane, a certain amount of damage to human body health; Especially when the ammonia concentration of air reaches a certain extent, it also may encounter fire explosion phenomenon, to use to do a good job of tight leakage protection.

Looking for an innovative range of start capacitor suppliers refrigerant gas products? Hangzhou E cool refrigeration Co.,Ltd supplies a diverse range of consumer, commercial and specialty industrial products including air conditioner capacitor, start capacitor suppliers, start capacitor suppliers,etc.Click Arkool Refrigeration to learn more!

As a result, consumers will reward Arkool with leadership sales, profit, and value creation, allowing our customers in which we live and work to prosper.

We focus on operational procedure and manufacturing facilities of refrigerant gas.

This is especially true when Hangzhou E cool refrigeration Co.,Ltd have got a global business that's building bridges between manufacturers and customers across the globe.

start capacitor suppliers air conditioner capacitor with start capacitor suppliers are used extensively in start capacitor suppliers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect