Common charging refrigerant refrigeration equipment method and deficiency

common refrigerant filling method and lack of:

1, hand contact suction, exhaust pipe, copper pipe perception of heat and cold; Everyone to the feeling of hot and cold, if your hands are long calluses, you perceive had higher temperature than the practice. General human feel is very hot, about 37 ℃ higher than the below 37 ℃ feeling is cool. Skin temperature limit for 49 ℃ of perception, so your hand perception of metal tube temperature of indeterminacy of dispute is really temperature.

2, investigate the bubbles in the liquid lens; There are air bubbles shows shortage of refrigerant, but liquid pipe pressure loss also can cause bubbles. If the liquid pipe pressure loss is very big, the liquid refrigerant will flash as gas, flash gas flow in expansion valve will cut the flow of refrigerant will erode expansion valve. Supercooling degree is small, if the system pressure loss is simple in sight to see in the mirror of bubbles. This moment to continue filling refrigerant to eliminate air bubbles, you will find that the high pressure rise and cause a jumping machine. Obviously this method can not correctly judging system of refrigerant injection quantity. 3, measurement of concave and convex pressure; In the process of refrigeration system maintenance of protection, the traditional dual pressure table is all over, the dual pressure table there will be wrong. Many dual pressure table using the calibration for a period of time will be a pointer, as otherwise the dial reading read from and often present pointer swing. Pressure after spend must find full temperature point, and real time full temperature could not be completely accurate, finally also will present the heat/cold degree value error, this method can only see the status of system in the past period of time, rather than the condition of real-time operation. But the refrigerant filling quantity and heat/cold degree is the key parameter of system operation. 4, the measurement of compressor current; Use more this way, but note that the test current is different in different circumstances, such as current acceptor power supply voltage, voltage error caused by the influence of current error, the refrigerant filling caused by excessive current change, such as 5, and calculated the heat; 6, investigation on the suction pipe condensation conditions; If the evaporator air volume is normal, found that the refrigerant according to the load change through the evaporator, tube to prevent the frost formation. If the load reduction, the liquid refrigerant will flow through the evaporator, enters the suction, surrounding the water vapor in the air condenses on the copper tube. If you have meet the liquid refrigerant, tube will attack. But when thermodynamic expansion valve system, dew tube does not suggest that the refrigerant charged note amount is too much, the reason is that will take the initiative to regulate the temperature of the expansion valve. Visible investigation discriminant filled volume of the refrigerant suction frost is not scientific, weighing note 7. Weighing filling method need to manufacturers on the nameplate indicates the filling amount, but in the process of practice, there are many refrigeration equipment self-assembly, filled volume of the no mark, and filling refrigerant on many online, need accounting refrigerant filling amount, this method of calculation is too complicated.

tag: & nbsp  & NBSP environmental protection refrigerants

Nowadays, the adoption of air conditioner capacitor in start capacitor suppliers industry is quite common.

All of the experts Hangzhou E cool refrigeration Co.,Ltd consulted stressed that the best recovery plans are the ones made before you need them, not afterward.

Technology upgrades can pay for themselves quickly by improving refrigerant gas and enabling employees to accomplish more in less time. It may be time to focus on start capacitor suppliers to ensure they run smoothly and efficiently.

Hangzhou E cool refrigeration Co.,Ltd is a initial company that supports expertise in searching marketing solutions.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect