In the use of cold storage, will inevitably faced with the choice of refrigerant, depending on the cold storage, refrigerant mainly can be divided into ammonia refrigeration system and freon refrigeration system two kinds big, this is what we often mentioned 'ammonia library' and 'fluorine library'. Want to make the use of cold storage effect is best, you must choose reasonably refrigerants, only in this way can make the use of cold storage performance more stable and help save the energy consumption of the use of the user.

1, direct expansion fluid for

refrigerant directly through the refrigerating unit, accumulator expansion valve, then flows through the evaporator and the cooling tube, the evaporator and the cooling pipe, to provide the role of the refrigerant to cold storage. This way of using although simple, but it is difficult to control the amount of feed liquid refrigerant, it is easy to affect the cold storage refrigeration effect, is a kind of refrigeration freon refrigeration system is more common.

2, gravity feed liquid

gravity feed liquid is also more commonly used a refrigeration refrigerator model, its in the middle of the evaporator and expansion valve added a gas-liquid separator, the refrigerant after reach a certain amount of liquid, directly for the static pressure of liquid column, will supply cold storage refrigeration liquid cooling equipment. For this kind of cooling mode, the most commonly used refrigerants is ammonia refrigeration, which can be through the ammonia liquid separator, the cold storage refrigeration equipment to provide enough refrigerant, ensure the normal operation of the refrigeration system.

3, liquid pump cycle for

pump cycle for liquid is also called for liquid ammonia pump, the main can be divided into aspirant, under and on down into the two ways, both can effectively ensure the cold storage refrigeration system of refrigerant supply, refrigerant refrigeration equipment, to play the best cooling effect. For the regulation of liquid ammonia pump, but had better have multiple pipelines, it can be adjusted by liquid, let it to place such as refrigeration, freezing room for liquid, to ensure that the refrigeration effect.

refrigerant gas are among the best and the long known , which plays an essential part in automatic manufacturing.

Do you want start capacitor suppliers air conditioner capacitor? We also have start capacitor suppliers. visit Arkool Refrigeration to know more.

We attach a great importance to domestic market and knows the importance factors of manufacturing refrigerant gas, such as producing methods, etc.

Hangzhou E cool refrigeration Co.,Ltd really created a whole persona around air conditioner capacitor’s manufacturing and selling, and it's so innovative that people really respond to it.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect