Central air conditioning of commonly used refrigerants and blunt refrigerant injection test

Refrigerant is the working medium of the central air conditioning refrigeration cycle, refrigerant through evaporation in the evaporator heat absorption, condensed in the condenser heat cycle to achieve the goal of refrigeration. Freon is currently widely used refrigerants, its variety, to avoid the trouble of writing the formula is, also in order to facilitate memory, people developed a simplified code to represent a variety of freon refrigerant, such as everything, R22, r410a. Now commonly used in central air conditioning two different refrigerant R22 and R410A. But the average user doesn't know the difference between these two kinds of refrigerants, don't know which one to use good refrigerant. Below to learn about these two kinds of refrigerants. What is a, R22 and R410A? 1, 2 fluorine R22 chemical called a methyl chloride, freon is a member of the family, as part of the hydrogen CFCS. We are using mostly refrigerants of R22. Because of the refrigerant of the ozone layer has a great deal of harm, according to the regulations of the Montreal protocol, * * out to 2020 years ago. 2, R410A is a kind of new refrigerants. New refrigerant R410A composed of two kinds of quasi azeotropic mixture, mainly include hydrogen, fluorine and carbon element, has a stable, non-toxic, superior performance, etc. At the same time as a result of not containing chlorine, so will not react with ozone, which does not destroy the ozone layer. In addition, the adoption of new refrigerant of the air conditioning in terms of performance also improved. R410A is internationally recognized so far used to replace proper refrigerant R22 *, and in Europe and the United States, Japan and other countries with widespread. Second, why want to replace R221 with R410A, R410A belongs to low toxicity, display burning transmissibility. Ozone depletion coefficient is 0, 2, R410A refrigerant R22 ozone depletion coefficient of 0. 05. 3, when using R410A system than the total heat transfer characteristics of R22, so can improve system efficiency, and reduce heat exchanger heat transfer area. Three, R410A and R22 has the following several different features of 1, R410 A consists of HFC - 32 ( R32) And HFC - 125 in weight than the 50 ﹪ mixture refrigerant, for nearly azeotropic mixture refrigerant. But for a single material refrigerant R22. 2 operation pressure is higher than R22, R410A about 50 ~ 70%. 3 is larger than that of R22, R410A vapor density. The system of the same capacity, the refrigerant mass flow rate is the same. Because of the gas piping are the same diameter, so R410A steam flow rate compared with about 30% slower R22. 4, for R32 molecules with high polarity, R410A is more soluble than R22. Four, the right to filling refrigerant in the refrigeration system in actual application, some of the following methods often can use testing adequacy of refrigerant in the refrigeration system, let's resolve the disadvantages of the filling way: 1, with the hand touch the suction, exhaust pipe perception of copper tube heat and cold; 2, observing the air bubbles in the liquid lens; 3, measurement of high and low pressure; 4, measure the compressor current; 5, and calculated the heat; 6, watching what is on the condensation of the suction; 7, weight note.

Wow, this sounds like a bit of a cruel question, but it is a vitally important question to ask yourself if you are struggling with your start capacitor suppliers and you would like to stop the refrigerant gas problem.

If you cannot find the specific type of that is best for your business in the above mentioned guide, you can visit Arkool Refrigeration for the best consultants specializing in this field, who can recommend the your are looking for. Customization is warmly welcomed here.

The risk of start capacitor suppliers is reduced by start capacitor suppliers with the consumption of .

Unlike the start capacitor suppliers, the is more flexibly used in accasions where start capacitor suppliers .

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect