loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Automotive air conditioning not refrigeration, check the fault in a timely manner to eliminate these aspects

< p > has arrived in summer, air conditioning has become a indispensable configuration while driving. But the driver of a lot of friends will find air conditioning is not cold, in the process of driving effect on driving experience, why suddenly so good carry of the air conditioning not refrigeration? Some owners added refrigerants can not solve, appear such circumstance, the following equipment is the check. < / p > < p > < / p > < p > air conditioning refrigeration effect is poor, cold wind blow out less, go first to check the air filter. Most models of air-conditioning filter arrangement in the co-pilot handrails box, need to remove the four card buckle can remove the air filter, also have arrangement in the engine cabin near the passenger side of the bottom of the front windshield. If air conditioner filter serious congestion, need to be replaced; If the surface dust too much, you can use compressed air blowing off the dust. < / p > < p > < / p > < p > if air conditioning refrigeration effect is poor because of the condenser surface dirt, you need to clean the condenser. Condenser plot generally use water cannons, that is, washing with water cannon, due to the condenser cooling material is aluminum material quality of a material soft, so particular attention should be paid when cleaning the surface of the condenser. < / p > < p > a is pay attention to the nozzle pressure don't too much, it does not carefully; < / p > < p > second, pay attention to the jet Angle, should first observe the condenser cooling fin Angle, the jet Angle is consistent with the fin Angle. Bear in mind that the above two considerations, otherwise it will damage the radiator, consequences do more harm than good. < / p > < p > third, monitor the performance of the refrigerant leakage and compressor parts; < / p > < p > < / p > < p > refrigerant leakage inspection is also very simple, first observed a pipeline joints, especially prone to refrigerant leakage between rubber and metal pipe ( Can use the bubble method for inspection) Check the rubber pipe, and the other for aging, crackle refrigerant leakage is also easy to happen. , of course, the most accurate method is to use fluorescent method, the fluorescent powder filling the pipe line of refrigeration system, press the A/C switch caused refrigeration cycle to work, to observe with ultraviolet lamp, if there is leakage, will under the action of ultraviolet light-emitting phosphors. Found refrigerant leakage must troubleshoot again filling refrigerant, otherwise is a waste of money. < / p > < p > < / p > < p > in addition, the method of observation can be used for checking the compressor and the cooling fan, turn on A/C switch, observe whether the compressor is off work, in the vehicle temperature reaches above 90 ℃, the cooling fan is off work, these checks are relatively simple. < / p > < p > < / p >

Hangzhou E cool refrigeration Co.,Ltd's has been able to achieve excellent performance in an extremely competitive industry.

Hangzhou E cool refrigeration Co.,Ltd is committed to supplying the consumer and our customers with the finest, high-quality products and to leading the industry in air conditioner capacitor start capacitor suppliers.

For most children start capacitor suppliers is a struggle. If that is also the case for your children, find the solution at Arkool Refrigeration.Arkool are your best choice.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect