loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Automobile air conditioning refrigeration effect is poor, how to deal with car air conditioning is not cold

Hot day, no one want to car air conditioning can give a little, but many owners reflected, the irritating air-conditioning outlet as if it was supposed to odds and we generally, out of the air conditioning is not cold. Automobile air conditioning refrigeration effect is poor what should I do? So what do we know about the car air conditioning is not cold today. Four solutions to air conditioning refrigeration effect is poor: 1, of course, we choose the simple and direct method, then adjust the direction of the wind, according to the principle of air convection, heat is going up, going down and air conditioners. So, we should put air-conditioning outlet to the oblique upper part, using the law of heat up cooling down, in the process of cold air drop, can give the car rapidly cooling, at the same time pay attention to in front of the air conditioning outlet, try not to put ornaments, will affect the air conditioning refrigeration effect. 2, if it doesn't work, then there should be a little more to link. Check the air filter, if your car for a long time have no for maintenance, it is likely to be affected is mesh too dirty air conditioning refrigeration effect, that is about to clean or replace the air filter. And replace the air filter method is simple, generally speaking, the air conditioning filter behind the glove box, if your car is not, please refer to the user manual in detail, the new air conditioning filter must be installed in the direction of the import and export right. 3, condenser too dirty may cause poor cooling effect, the car in front of air conditioner condenser, cleaning method has simple also have trouble, you can direct the pipe of condenser to wash; In addition to unpick and wash, this method need to take out the condenser, ensure that the clean degree of cleaning. If you don't want to yourself, or to the professional car wash. 4 or too little refrigerant refrigeration dose line or lack of air conditioning system is insufficient, the pressure is reduced, smaller, heat along with refrigeration bad will happen. At this moment need to refill refrigerants, by the way, check for leaks. If the above measures still doesn't work, so this means that the air conditioning system failure, such as compressor damage and damage of expansion valve, the suggestion to the professional maintenance shop or 4 s shop for maintenance.

Hangzhou E cool refrigeration Co.,Ltd helps high-profile clients build strategic relationships that drive company growth, investments, funding and more. There are many make-or-break details involved in the day-to-day manufacturing within our company.

We would like to offer our comprehensive service to our customers who interested in refrigerant gas.

For optimal start capacitor suppliers, choose a high-quality air conditioner capacitor system and make sure a certified installer sets it up.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect