Air energy water heater refrigerant leakage problem and solutions_maintenance

  【】Refrigerant leakage is one of the most common faults in the heat pump system. The leakage has technological problems, such as poor welding quality, friction between copper pipes or between copper pipes and the casing, etc. The parts themselves, such as pressure gauges, high and low pressure switches, pressure relief valves, refrigerant charging check valves, etc., may also cause refrigerant leakage due to their own quality problems.

The performance of    heat pump after refrigerant leakage is that all components can operate normally, but the heating capacity is greatly reduced or even lost. The leakage of refrigerant will also be accompanied by the reduction of oil and compression. If the machine runs for a long time, but it cannot reach the predetermined water temperature and shuts down, and the return air volume is too small, it will cause the temperature of the compressor casing to rise, the lubrication deterioration, and the risk of the compressor.

  The method of judging refrigerant leakage is to check the return pressure of the compressor when the heat pump is running. If it is lower than the normal value, it may have leaked. In addition, an ammeter can also be used to detect the operating current. If the current is significantly lower than the normal value, it can also be determined that the system has leaked. Another more intuitive and convenient method is to observe the evaporator: due to refrigerant leakage, the low pressure pressure drops, the heat pump evaporator tends to increase in frosting, and unreasonable frosting may occur (such as when the temperature is above 10°C). frost). After a refrigerant leak occurs, you should immediately start to make simple and repair the leak. You can't replenish the refrigerant hastily. The leak cannot be found and the leak is completed. The refrigerant leak will continue, and at the same time, the refrigerant must be refilled. Pay attention to replenish the refrigerating machine oil in an appropriate amount.

Hangzhou E cool refrigeration Co.,Ltd is trying to institute social good changes this relationship because it averts a firm's resources from its core task of increasing profits.

If you are ready to stop the problem of start capacitor suppliers and go back to normal, contact us at Arkool Refrigeration. Hangzhou E cool refrigeration Co.,Ltd is ready to help you out.

start capacitor suppliers air conditioner capacitor offer a wide range of start capacitor suppliers and gave the user the choice of start capacitor suppliers, start capacitor suppliers and start capacitor suppliers.

More than half of customers said they have faith with Hangzhou E cool refrigeration Co.,Ltd and refrigerant gas.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect