Air conditioning refrigeration machine does not turn is what problem, the maintenance of air conditioning machine does not turn method

air conditioning machine does not turn not refrigeration reason: 1, remote control mode is not correct. Check the remote control set is a cooling mode. Using air conditioning remote control, the adjustment to the display state of 'cooling' or 'snow', or 26 degrees Celsius temperature setting to 26 degrees. 2, it is also possible that the power problem, can observe the work if there is a sound (outdoor Including the fan and the compressor outdoor) 。 If the outdoor fan operation, the control circuit. At this time should observe whether the compressor is started, if the compressor is not started, you should check whether the power supply is normal. 3, consider whether the voltage is not enough reason, even if air conditioning can't boot, check the mechanical and electrical source is there is electricity or voltage at rated voltage. If it is not the cause of the low voltage please check whether indoor and outdoor machine to connect to, whether the wire aging, indoor machine main wiring is correct, or change the machine within the mainboard. 4, lack of fluorine, general air conditioning open half an hour later, if you can reach the set temperature ( The capacity to match the room air conditioning) , run the light is on for a while out for a while, Like a refrigerator compressor, open for a while to stop for a while) , but otherwise, the phenomenon of lack of fluorine. Air conditioning refrigeration machine does not turn what _ air conditioning machine does not turn the method of air conditioning machine does not turn the maintenance method 1, power supply, voltage problem

1) if the power supply has a problem, outdoor power supply problem then there is no way to air conditioning power supply, no electricity, nature will not be able to run. Air-conditioning maintenance methods: check whether the power supply is aging, short circuit or plug is loose, and related air conditioning repair or replacement of the power supply circuit. (2) voltage problems this situation is very common in the summer, because summer big power consumption, the power supply voltage is prone to voltage instability or voltage is insufficient, lead to the power supply voltage outdoor is insufficient, can't run. Air conditioning voltage maintenance method: check if air conditioning supply voltage is too low or unstable. If is not stable, add stabilizer. If the power supply voltage is not enough, please consult your local power supply bureau. 2, air conditioning compressor starting capacitor damaged or motor fault if you have any questions or the start of the compressor capacitor motor itself fault occurs, the compressor will not be able to start, lead to outdoor cannot run. Air conditioning maintenance methods: replace the compressor motor start or replaced. 3, air conditioning separate-bodied air-conditioners are not reason if the condenser is too dirty or external fan fails, if the condenser severe congestion or external fan because of failure to rotate, seg will not be able to heat dissipation, high temperature caused by, and there will be a protective stop the phenomenon, this will stop the start. Air-conditioning maintenance methods: clean or repair and replacement of air conditioner condenser external fan.

Hangzhou E cool refrigeration Co.,Ltd is trying to institute social good changes this relationship because it averts a firm's resources from its core task of increasing profits.

For more advice on tips, please visit our website Arkool Refrigeration. Do not hesitate to contact us if you are interested.

Hangzhou E cool refrigeration Co.,Ltd has been focusing on reaching the ideal profits.

Hangzhou E cool refrigeration Co.,Ltd deems that we can drive consumer transactions using high-tech tools like artificial intelligence and cognitive data sets.

Hangzhou E cool refrigeration Co.,Ltd can promise you that we never conceded on the quality standards of our products.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect