Air conditioning refrigerant r410a technical characteristics

Air conditioning refrigerant r410a technical features you understand? Don't understand it doesn't matter, small make up take you to know about the below. R410a refrigerant is a hybrid of HFC - 32 and HFC - 125 ( Mass ratio of 50% / 50%) 。 It is instead R - 22 refrigerant air conditioning system fixed, but. 。 。

air conditioning refrigerant r410a technical features you understand? Don't understand it doesn't matter, small make up take you to know about the below.

r410a refrigerant is a hybrid of HFC - 32 and HFC - 125 ( Mass ratio of 50% / 50%) 。 It is instead R - 22 refrigerant fixed air conditioning system, but is cannot be applied on the original R22 equipment. It is not a substitute for R22. R - 410 a has proved can effect comparing increased 5 ~ 6%, compared to R - 22. It also has a R - 22 a higher capacity and release the pressure, make the design of the air conditioning device is smaller and compact.

it is HFC - 32 and HFC - 125 almost azeotropic binary mixture, its floating temperature below zero. 2℃。 It is very similar to the properties of azeotrope, can see it as a single refrigerant. This means that they won't destroy the combination of the system and its proportion, also won't change when leakage. Cylinder diameter cannot too big, the compressor discharge capacity is not more than 32 cm3, so the piston machine can separate combination and the compression force is in danger. Steaming compression cannot exceed a certain space, danger! It is very important, so to add fluoride must be done in the liquid.

r410a refrigerant thermodynamic properties of their excellent can use more compact compressor, smaller diameter tube, and a higher speed and better equipment, because it has lower energy loss. R410a refrigerant is compatible with oil and mineral oil or alkyl benzene, because r410a won't mix with them. For R - Is 410 a specified oil polyols ( POE) Oil. The oil should not be exposed in the open air, and can only be opened before use. Tools and parts must be for r410a refrigerant. Do not use the conventional instrument filling refrigerant, measuring pressure and watching them ( Tube, extraordinary) In case of one thousand.

the above introduction about the r410a refrigerant to the over here, hope to be able to bring you some help, if you have a demand on refrigerant r410a, welcome consultation discussion with us, we wholeheartedly at your service.

149

Hangzhou E cool refrigeration Co.,Ltd has famous reputation in worldwide.

If you cannot find the specific type of that is best for your business in the above mentioned guide, you can visit Arkool Refrigeration for the best consultants specializing in this field, who can recommend the your are looking for. Customization is warmly welcomed here.

This can benefit Arkool by helping it target those investors and consumers who are specifically interested in its type of product or service.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect