loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Which add refrigerant gas, which refrigerant must add liquid?

by:Arkool     2020-03-11
< p> a, filling principle < / p> < p> 1, liquid filling < / p> < p> filling liquid refrigerant that is refrigerant cylinders upside down, because is liquid refrigerant inside the cylinder, the cylinder upside down, by adding the liquid tube to the refrigeration system is a liquid refrigerant. Note: the part of the cylinder is put fluoride mouth can reach to the bottom of the cylinder, the cylinder is though, are made, but added the liquid refrigerant. < / p> < p> < / p> < p> 2, gas filling < / p> < p> filling gaseous refrigerant is refrigerant cylinders is made; Because the upper cylinder space is gaseous refrigerant, so is the gaseous refrigerant of the refrigeration system is added and now. < / p> < p> < / p> < p> why adding gas and liquid, why some refrigerant gas, liquid some want? < / p> < p> < / p> < p> 1, the three concepts < / p> < p> < / p> < p> single working medium refrigerants, non azeotropic mixed refrigerant and azeotropic refrigerants < / p> < p> < / p> < p> single refrigerant substance: refrigerant components only a working medium; Such as R22, R290; Non azeotropic refrigerants: two or more different refrigerant mixture to a certain percentage of the refrigerants, it in saturated state, the composition of gas liquid two phase composition; For example, R404A, R410A; < / p> < p> < / p> < p> azeotropic refrigerants: there are two or more different refrigerant mixture to a certain percentage of the azeotrope, this kind of refrigerant under certain pressure can keep certain evaporating temperature and the composition of gas liquid two phase keep ratio unchanged. For example: R500, R508A; < / p> < p> < / p> < p> 2, liquid or gas? < / p> < p> 1) Whether gaseous or liquid refrigerant, single working medium inside composition will not change, so the filling refrigerant can filling gas. < / p> < p> 2) , azeotropic refrigerants although composition is different, but the boiling point is the same, so the composition of gas and liquid two same, so you can filling gas; < / p> < p> 3) , non azeotropic refrigerants due to the boiling point is different, so the liquid refrigerant and gas refrigerant composition is not the same, actually as if gas, will inevitably lead to add refrigerant components, such as only added a gaseous refrigerant, so can only add the density of its liquid. < / p> < p> < / p> < p> three, how to distinguish the single working medium, azeotropic, non azeotropic? < / p> < p> single working medium, azeotropic refrigerant can filling gas; Non azeotropic refrigerant must be filling liquid; But how do we tell azeotropic, non azeotropic refrigerants? To see whether the refrigerant type; According to the refrigerant naming rules: < / p> < p> < / p> < p> azeotropic refrigerants: behind the R of the first number is '5', behind the two Numbers according to the practical order number. R507 < / p> < p> < / p> < p> non azeotropic refrigerants: behind the R number order no. 400, in accordance with the order. R411 < / p> < p> < / p> < p> 4, why the azeotropic refrigerant must add liquid, why the azeotropic refrigerant must add liquid? < / p> < p> < / p> < p> let's take a look at R410A refrigerant, obviously, '4' at the beginning of refrigerants, affirmation is azeotropic refrigerants, composition is as follows: R32, Methylene fluoride) : 50%; R125 ( Five fluorine ethane) : 50%; < / p> < p> < / p> < p> check table shows R32 and R125 refrigerant physical properties of different boiling point, which is why the cause of the non azeotropic refrigerants; And let stand, when R410A refrigerant cylinders R32 R125 due to different boiling point, will inevitably lead to the refrigerant cylinders on partially evaporating gaseous refrigerant and components, it is not 50% R32 + 50% R125, due to the low boiling point R32, so probably on the part of the refrigerant is R32 components. If add gaseous refrigerant, added is refrigerant R410A, but R32. Other non azeotropic refrigerants can only add up the cause of liquid. < / p> < p> < / p>:
If you are looking for convenient, affordable , Arkool brings plethora of options to suit your requirements and budget both. Check Arkool Refrigeration for more details.
go to Arkool Refrigeration to get an amazing offer at favorbale price. the air conditioner capacitor start capacitor suppliers actually works and is worth a try.
There have been conclusive evidence on 's role in start capacitor suppliers and start capacitor suppliers.
start capacitor suppliers refrigerant gas are used largely for start capacitor suppliers such as start capacitor suppliers.
Arkool provides a number of start capacitor suppliers designed to handle start capacitor suppliers.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...